CO2-Insufflator

UCR

UCR

Contents start

CO2 insufflation is becoming the standard-of-care for colonoscopy and balloon-assisted enteroscopy. The UCR makes CO2 insufflation simple and easy, reducing discomfort to patients. It is a simple-to-operate, compact device and can be operated by endoscopists with no additional technical support.

Carbon dioxide (CO2) insufflation has been shown to improve intubation depth during balloon-assisted enteroscopy and reduces post-procedure pain. The UCR is designed to facilitate efficient CO2 insufflation, ensuring optimal patient outcomes. It is simple to operate, with a single button on the front panel to control gas flow, and is compact, allowing it to be incorporated into existing endoscopy stations. The UCR can be connected to a gas cylinder via a dedicated hose, or directly to the hospital’s medical gas supply; either procedure requires no additional technical support.

  • Add to Watch List
  • Brochure

Reduced patient discomfort due to distension

CO2 is absorbed by the body 150 times faster than air, reducing patients’ discomfort due to intestinal distension during and after enteroscopic procedures.

Easy-to-use controls allow effortless CO2 control

The UCR features a single button to start and stop the flow of CO2 on the front panel, making the device extremely easy to use.

Compact device fits into standard endoscopy set-up

The UCR is small and compact and has been designed to fit easily into a standard endoscopy station, without the need for additional trolleys.

Easy to set up

The UCR is easily set up by connecting to a gas cylinder with a dedicated cylinder hose or by connecting directly to the hospital’s medical gas supply.

Single-button control

The UCR has a simple start/stop button on the front panel, enabling you to control gas flow rates efficiently and without distractions, and saving gas wherever possible.

Connection to gas cylinder via dedicated cylinder hose

A dedicated cylinder hose ensures easy exchange of carbon dioxide cylinders. This procedure is simple, fast and does not require any technical assistance.

Connection to hospital medical gas supply

You can also connect the UCR to the hospital’s medical gas supply, ensuring an unlimited supply of gas, and meaning you do not have to change gas bottles during complex endoscopic procedures.

Compact and lightweight

You can also connect the UCR to the hospital’s medical gas supply, ensuring an unlimited supply of gas, and meaning you do not have to change gas bottles during complex endoscopic procedures.

Compact and lightweight

The UCR is compact in size and lightweight at just 4.9 kg, allowing you to incorporate it easily into your existing endoscopy station without the need for an additional trolley.

High flow rate

The UCR provides high gas flow rates, allowing you to rapidly insufflate patients, especially during colonoscopy.

Power requirements Voltage (AC) 100 –120 V (USA), 100 – 240 V (Other areas)
Frequency 50/60 Hz
Input 40 VA
Voltage fluctuation Within ±10%
Dimensions   125 (W) × 300 (D) × 150 (H) mm (housing dimensions)
Weight   4.9 kg
Applicable gas   CO2 gas for medical use (Connectable to CO2 cylinder or medical gas pipeline)
Air feeding pressure Maximum pressure feed 45 kPa

Contents end