Stone Extraction Balloons

Stone Extraction Balloons

Contents start

The Multi-3V Plus single-use stone extraction balloons combine excellent balloon durability with efficient stone extraction capabilities to provide more choice and flexibility for ERCP physicians. The models are available as over-the-wire and distal-wireguided versions in different sizes from 8.5 to 15 mm and 15 to 20 mm and with the injection port above or below the balloon.

  • Add to Watch List
  • Brochure

Excellent balloon durability

Thick, high-quality latex increases the durability and reduces the risk of balloon bursting during stone extraction.

Distal-wireguided or over-the-wire design

The distal-wireguided design enables a quick instrument exchange and facilitates the extraction of multiple stones with the guidewire still in place.

Two different balloon sizes

The Multi-3V Plus comes in two different sizes: 15 mm maximum balloon diameter and 20 mm maximum balloon diameter for dilated ducts.

Multiple balloon sizing

Each ballon can be inflated to one of three diameters: 8.5 mm, 11.5 mm and 15 mm for the 15 mm balloon version or 15 mm, 18 mm and 20 mm for the 20 mm balloon version.

Pre-measured syringes

Clearly marked syringes enable precise inflation of each balloon without checking the markings on the syringe.

Multi-3 V Plus - Single-use stone extraction balloons

V-System single-use triple lumen stone extraction balloons

  • Choice of distal wireguided or over-the-wire design
  • Multiple balloon sizing
  • Additional balloon size with 20 mm max. inflation diameter for dilated ducts
  • Excellent balloon durability
  • Integrated C-Hook, V-Sheath (for over-the-wire type) and V-Marking
Multi-3V Plus
  • Single use only
  • This device is packed sterile
  • This device is visible under fluoroscopic control
  • This device has a luer-lock connector or cleaning adaptor for flushing
  • This device is compatible with a 0,035" guidewire
  • This device allows for the instillation of contrast medium

Article name Quantity Min. working
channel Ø
Working
length
Balloon
sizes
Injection
placement
Sheath
design
Area
compatibility
B-V232P-A 1 2.8 mm 1900 mm max. 15 mm above Over the wire For billiary and pancreatic procedures
B-V232P-B 1 2.8 mm 1900 mm max. 15 mm below Over the wire For billiary and pancreatic procedures
B-V242Q-A 1 3.2 mm 1950 mm max. 15 mm above Distal
wireguided
For billiary and pancreatic procedures
B-V242Q-B 1 3.2 mm 1950 mm max. 15 mm below Distal
wireguided
For billiary and pancreatic procedures
B-V432P-A 1 3.2 mm 1900 mm max. 20 mm above Over the wire For billiary and pancreatic procedures
B-V432P-B 1 3.2 mm 1900 mm max. 20 mm below Over the wire For billiary and pancreatic procedures
B-V442Q-A 1 3.2 mm 1950 mm max. 20 mm above Distal
wireguided
For billiary and pancreatic procedures
B-V442Q-B 1 3.2 mm 1950 mm max. 20 mm below Distal
wireguided
For billiary and pancreatic procedures
B-V233V-A 1 2.8 mm 2400 mm max. 15 mm above Over the wire For billiary and pancreatic procedures