Ease of use
The SIF-Q260 boasts a simple, user friendly operation at every step of the way from set-up to observation and treatment.
Clinical efficiency
Efficient hand or foot controls, and an automatic pressure control, eliminate complex operations and reduce procedure time.
Hypoallergenic, latex-free design
The patient-friendly, latex-free design includes a hydrophilic lubricant coating for excellent lubrication between the scope and splinting tube.
Advanced imaging and connectivity
The SIF-Q260 supports Narrow Band Imaging (NBI) observation for more detailed view of mucosal morphology. It is compatible with a wide range of systems.
Outstanding high-resolution imaging
A high-resolution CCD chip in the distal end provides high quality images of finer details. Combining this with the EVIS LUCERA SPECTRUM system adds the power of Narrow Band Imaging (NBI) observation for views of the small intestine.
Wide 2.8mm diameter channel in a 9.2mm scope
To improve maneuverability of insertion, the SIF-Q260 features a distal end diameter of just 9.2mm whilst maintaining high-resolution image quality. An instrument channel diameter of 2.8mm meets a range of enteroscopy treatment options.
Optimised distal end/bending section for smooth insertion
By optimising both the distal end length and bending section radius, the SIF-Q260 extensive angulation capability allows acute turns in the small intestine, supporting a smoother insertion.
Simple cleaning disinfection and sterilisation
The SIF-Q260 Single Balloon Enteroscope System incorporates a balloon on the splinting tube to remove an extra step in the cleaning process. The SIF-Q260 can be cleaned the same way as conventional scopes.
Advanced balloon control unit for trouble-free operation
Automatic pressure control function for maximum reliability
The OBCU is equipped with an automatic pressure control function. This safety function operates to suppress the balloon pressure and maintain it within a prescribed range.
Simple configuration facilitates all steps from setup to operation
All you have to do to set up the OBCU is connect the overtube. Operation is equally simple. Just press the control button repeatedly to inflate or deflate the balloon.
(1) Install the reserver tank and connect it to the exhaust port.
(2) Attach one end of the insufflation tube to the plug on the reserver tank.
(3) Attach the other end to the insufflation plug on the overtube.
Operation possible either on the compact remote control or the front panel
Besides the front panel controls, you can operate the OBCU with this convenient, ergonomic remote control.
Specification
Power |
100 V - 240 V AC 50/60 Hz |
Consumption electric power |
150 VA |
Set Pressure of Balloon |
5.4 kPa
+ 2.6 kPa - 0.0 kPa
|
Size (WxHxD) |
374x151x486 mm |
Weight |
11 kg (Balloon Control unit) 0.4 kg (OBCU Remote Controller) |