Video Duodenoscope

JF-260V

  • NBI
JF-260V

Contents start

The Olympus EVIS LUCERA DUODENOVIDEOSCOPE JF-260V offers users a wide 3.7mm channel that suits a spectrum of ERCP procedures, from cannulation to placement of a 10 Fr. stent. It is easier to use thanks to the innovative V-Groove forceps elevator which simplifies device manipulation and replacement.

The Olympus EVIS LUCERA DUODENOVIDEOSCOPE JF-260V offers users a large instrument channel measuring 3.7 mm across for expanded treatment options in the bile and pancreatic ducts. This suits a wide spectrum of ERCP procedures, from cannulation to placement of a 10 Fr. stent. It is also easier to use thanks to the innovative V-Groove forceps elevator which simplifies device manipulation and replacement in duodenoscopy. Its slim-design - measuring 12.6 mm across at the distal end and 11.3 mm across at the insertion tube - allows for an excellent insertion capability.

  • Add to Watch List
  • Brochure

Large instrument channel

The large channel measuring 3.7 mm across allows for expanded treatment options in the bile and pancreatic ducts.

Innovative design V-Groove forceps elevator

This allows raising at a sharper angle; its unique V-shaped guidewire locking groove joins the guidewire's reactive force to lock it in position.

Slim design

Measuring only 12.6 mm across at the distal end and 11.3 mm across at the insertion tube, this allows for excellent insertion capability.

Detachable distal cover

Being able to remove the distal cover allows for easier cleaning of the scope tip.

4-way angulation and wide field of view

A 4-way angulation (120° up, 90° down, 110° right, 90° left) facilitates an easier approach to the papilla of Vater.

Ergonomically designed grip for ease of use

The easy grip on the JF-260V enhances torque performance and scope maneuverability; in addition, the easy-to-access control knobs improve user operability.

Scope ID function for effective data capture

The scope ID function retains individual scope information in the memory chip and displays it on the monitor. It also stores settings, such as Automatic White Balance, to facilitate endoscopy suite management.

Optical System Field of view 100°
Direction of view 15° Backward oblique viewing
Depth of field 5 to 60 mm
Distal End Outer diameter 12.6 mm
Insertion Tube Outer diameter 11.3 mm
Bending Section Angulation range Up 120°, Down 90°, Right 110°, Left 90°
Working Length   1,240 mm
Total Length   1,550 mm
Instrumental Channel Inner diameter 3.7 mm
Minimum visible distance 10 mm from distal end
Laser Compatibility   NO
High-Frequency Compability   YES
Scope ID Function   YES
EVIS LUCERA ELITE Video Processor CV-290

EVIS LUCERA ELITE Video Processor

CV-290

  • HDTV
  • NBI
  • Ground-breaking resolving power for efficient diagnosis
  • Brighter, more powerful Narrow Band Imaging
  • Outstanding, true-to-life image quality
  • Brochure
EVIS LUCERA ELITE Xenon Light Source CLV-290

EVIS LUCERA ELITE Xenon Light Source

CLV-290

  • HDTV
  • NBI
  • One-touch Connector
  • Brighter, more powerful Narrow Band Imaging
  • Improved ergonomics
  • Brochure
EVIS LUCERA ELITE Xenon Light Source CLV-290SL

EVIS LUCERA ELITE Xenon Light Source

CLV-290SL

  • HDTV
  • NBI
  • AFI
  • One-touch Connector
  • 300-watt xenon lamp
  • Optimises performance of HDTV-compatible scopess
  • Sophisticated filter systems for NBI and AFI
  • Brochure